Page 35 of 57 · scan clean
AAWSAP DIRD High Frequency Gravitational Wave Communications April 6 2010
UNCLASSIFIED//&OR Oii&ICI0L Ll&li QPIL¥
3.3.4 The Impact of Frequency Noise Improvements on FDMA and FHSS
The very low noise frequency standard that would be supplied by an HFGW FTS system would allow for much more efficient use of reserved frequency bandwidth. Frequency noise limits the type of modulation and manner of encoding that can be performed in frequency space, such as Frequency Division Multiple Access (FDMA) or Frequency Hopping Spread Spectrum (FHSS). HFGW can reduce frequency noise by providing a frequency reference with outstanding stability. For example, guard bands can be shrunk in FDMA, and frequency slices can be smaller and more stable in FHSS.
A frequency space representation of the FDMA and FHSS noise improvements are depicted in Figure 22.
High Freq Noise Low Freq oise
Case
Case
Larger Guard Bands
~~;.~
t
I
Smaller Guard Bands
.- r- ~
r- - - -
II
High Freq Noise Case
Fewer Freq
Symbols ,,,-·
t ~~
Low Freq Noise Case
Frequency~
(a) Frequency Division Multiple Access.
Frequency-;--+
(b) Frequency Hop Spread Spectrum .
Figure 22. The Impact of Frequency Noise Improvements on FDMA and FHSS
Efficiencies in guard-band structure can be defined as in Equation (14).
Guard band BW Efficiency = (Total Bandwidth - {Sum of Guard BW} )/Total Bandwidth (14)
Guard bands often consume 30 to 50 percent of assigned frequency space. While guard bands would still be required to allow for the side lobes of signals, the frequency error component would be eliminated. Similar efficiencies may be gained in the FHSS approach. A better knowledge of absolute frequency allows better frequency coding efficiencies, as seen in Equation (13) and depicted in Figure 21.
3.4 POSSIBLE FUTURE UPGRADES TO THE FTS DEVICES
Per the 9 Feb 2009 issue of New Scientist, optical lattice clocks are under development that will lead to a dramatic improvement over the current standard Cesium atomic oscillation clocks that now provide frequency time standard references. Optical lattice clocks vibrate at optical frequencies rather than microwave frequencies, with the reference frequency mixed down via frequency combs to allow measurements back down in the microwave regime. Strontium lattice clock are already operating with measurement precisions of 1 part in 10 16, and theoretical performance approaches 1 part in 1018. At this precision one could measure the time delay caused by changing once centimeter in height in the Earth's gravitational field.
30
UNCLASSIFIED/ /FOP OiiiilCl.t.k l!ISI!!! l>flti