AAWSAP DIRD Biosensors and BioMEMS A Survey of the Present Field March 31 2010
UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥
Microcantilever based sensors fall into two categories: static sensors and vibrational sensors. Static sensing microcantilevers are usually covered with a gold film, which is then coated with a substance having a specific affin ity. Upon binding the specific analyte (such as a protein ), stress is generated resulting in bending of the microcantilever.
selective chemical layer
~
L ------------------------------·-1 s
The deflection is often measured using a
narrow light beam from a small laser. Light reflected off the bottom of the
♦ reacting chemical compound
cantilever falls onto a surface, where a
position sensitive detector (PSD) can
determine how much the beam bends. Typically the bend is exceedingly slight,
Figure 34. Principle of a Microcantilever That Bends When It is Loaded With an Adherent Mass
but the sensitivity of the optical readout system is high enough that small amounts
(nanograms to picograms) of adsorbed material can be detected. These devices are
mostly used for measuring th ings in the air and not well su ited for immersion in flu ids.
In vibrational sensing, an external motor is used to v ibrate the microcantilever through a certain range of speeds, and a sensing mechanism then reads out the amplitude of the vibration. By seeing at what speed the cantilever vibrates best, the resonant frequency is obta ined. As bioparticles bind to the microcantilever, the resonant frequency will be slower due to the increased mass.
The mass of attached analyte can be determined from the frequency of the microcantilever. The microcantilever has its own natural frequency w. When a biomolecule binds to the microcantilever, it changes the mass of the microcantilever. This in turn affects the resonant frequency. We can use that change to determine the mass that has been attached to t he microcantilever.
In some sense it is like a tuning fork that changes its pitch when touched. The surface has an affin ity for adhesion of a certain material and nothing else. When these materials are present, they adhere and increase the mass and so the pitch moves lower.
The sensitivity of these systems to the loaded mass increases as the mass of the cantilever beam decreases and with it the resonant frequency increases. Decreasing the overall dimensions of the beam results in an corresponding increase in their sensitivity.
37 UNCLASSIFIED/ {FOR OFFICIO! !PEii QDlk¥