Page 11 of 45 · scan clean
AAWSAP DIRD Biosensors and BioMEMS A Survey of the Present Field March 31 2010
UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 8NI.¥
The Neural Probe chip enables precise bi-directional positioning of the microelectrodes in the brain with a step resolution in the order of 8.8 µm. The thermal microactuators allow for a movement of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain.
The rest of the mechanism converts an oscillatory motion to a linear motion through a ratchet-type configuration. Figure 3 illustrates the basic unit where there are two comb like arrays on either side. These generate the actual force. They are connected to a cross piece that converts oscillatory motion in concert with a spring to a pulsatile linear motion of the vertical shaft. This connects to some gears which do a mechanical transformation.
..., fon•11,
~--- ~
Figure 2. Functional MEMS Micromachines Attached to Sensing Bioelectrodes. The gears have features as small as 50 microns, less than the size of a period on a printed page . (Courtesy of Dr. J. Muthuswamy, Bioengineering Department, ASU)
Figure 3. Schematic Diagram of a MEMS Motor Complete With a Method of Converting Oscillatory Motion to Linear Motion. (Courtesy of Dr. J. Muthuswamy, Bioengineering Department, ASU)
5
UNCLASSIFIED/ {FOR OFFICIO! !Pfli ODIi.¥