Page 73 of 156 · scan clean

Project Blue Book File on Tremonton Film Utah 1952

·code 01/Jrtrw/lbh
J12
UNCLASSIFIED
Serial:

Subj: Interpretation o:f Movies of Unidenti.f'ied Objects; progress report on

b. Densitometric teets:

Densitometric data were obtained with a Densichron, Mod.el 2150 manufactured b :- the Welch Scienti.f'ic Company. The 'D,nsichron has a scale
range or 0-3 . The procedure was to project each f'rame at approximately
22 times magnification onto a finely-grained-glass screen. The back­ ground. (sky) was then measured at several places and the density set to
3.0 (variations in background densities were in the order of 0.02 and were regarded as uniform) . A set of three readings were made of each of seven objects in Part I, and of the single object in Part III of the Utah Film. Readings were made o:f the entire Montana film.

Enclosure (6a and 8b) are graphs ot the density readings obtained of the two lower groups of objects in frames l-129 of the Utah film. Enclosure (9) is a density graph of the single object (94 frames) in Part III. Enclosure {10) is a graph where six successive Densichron readings were averaged and advanced one reading each deter­ minant.

Of the M:>ntana film, densities were plotted as above and are enclosures (ll) and (12).

The results of' the density readings may be questioned in that these objects varied in size so that at the minimum sizes the densichron probe was measuring the entire object, and at the maximum size the probe was measuring only a portion of the objects . Because of this situation only the largest readings obtained b scanning the objects were uaed.
It is understood that normal procedure would be to read the entire object. This was illlpossible with the equipment on hand.

In addition the film, with which this investigation was conducted,

is a duplicate of a copy. Thie raises the question as to whether the

central portion of the objects were burnt out during the duplication

processing. Density readings were made to compare the clear areas and

the objects. It was :found that the minimum difference is 0.4. This

indicates that relative luminosity may still be obtained with the pro­

cedure used. Concurrent with the density readings, relative sizes of

the objects were noted in order to correlate distance and luminosity.

Enclosure (13) is a plot of the same object wherein the relationship of

distance and luminosity can be detected in Utah .film.

•

3 Answers to Questions

l>OWDNECG.RLAASDSEIFDIEADT

ASFYTREARR12~-'.JY,..E.TA"TR>YSn~.

.-n.
L"i"''

•

•

DOD DIR 5200.10

Answers keyed to the questions contained in enclosure {7) of reference {a) are hereb:,- presented. They supercede those contained in reference (c) and present the final analysis as requested.

UNCLASSIFIED